Services Commercial Residential Service agreements About Contact Service areas Request a bid Call (303) 720-3954

Rooftop unit replacement, Greenwood Village

Replacing rooftop units in Greenwood Village

Packaged RTU changeouts with crane lifts, curb adapters and controls for Greenwood Village commercial buildings.

  • Insured
  • EPA-certified technicians
  • Design-build and plan-and-spec
  • 24/7 emergency response

East of I-25, Greenwood Village is one of the metro's densest office markets, with Denver Tech Center towers, corporate campuses and medical suites served by rooftop units, central plants and VAV systems. When those rooftop units reach end of life, Besties HVAC Solutions plans the lift, the curb, the utilities and the controls so changeout day is execution, not discovery.

Where we lift in Greenwood Village

Redevelopment in the Tech Center is turning older low-rise office parcels into mixed-use, multifamily and new Class A space, each with its own mechanical scope. RTU work clusters around the Denver Tech Center, Greenwood Plaza, the Orchard Road and Belleview Avenue office corridors and the Landmark mixed-use district.

Owners and managers in Greenwood Village usually replace RTUs for one of three reasons: a failed compressor or heat exchanger, rising repair bills, or a tenant change. We plan each changeout so the building reopens on schedule.

Greenwood Village project spec sheet

Rooftop unit replacement in Greenwood Village
ConfigurationsGas/electric, heat pump, electric heat, economizer, VAV
LiftCrane, rigging plan, street use where required
Typical pricing$15,000 to $60,000+ per unit, typical range, exact pricing after plan review or site walk
CountyArapahoe County
ElevationAbout 5,400 feet
Key areasThe Denver Tech Center, Greenwood Plaza, the Orchard Road and Belleview Avenue office corridors and the Landmark mixed-use district

What a Greenwood Village RTU changeout includes

After the set, we complete connections, economizer and controls setup, and a full startup on heating and cooling, then document each unit for the owner.

  • Roof survey of every unit
  • Replacement equipment selection
  • Structural and roofer coordination
  • Crane and rigging plan
  • Curb adapters or new curbs
  • Gas, electrical and condensate
  • Economizer and controls
  • Startup reports

Process

  1. Survey. Existing conditions or construction documents reviewed in detail
  2. Price. Scope, options and exclusions in writing, so the number holds
  3. Install. Scheduled work windows, protected finishes and clean sites
  4. Commission. Startup, balancing, controls and training before turnover

Local conditions in Greenwood Village

  • Homes from the 1970s through the 2000s often still have original ductwork paired with replacement equipment that was never resized.
  • Large finished basements and vaulted main floors create real temperature differences between levels, a classic zoning problem.
  • Offices and medical suites around the Tech Center rely on rooftop units and split systems that need scheduled maintenance, not only break-fix calls.

At about 5,400 feet, Greenwood Village equipment works in thin air, intense sun and hail. We select capacity with altitude correction, set gas equipment to the manufacturer's elevation guidance and plan outdoor equipment for hail exposure.

We also deliver rooftop unit replacement in nearby Cherry Hills Village, Centennial, Lone Tree and Englewood. For the full overview, including our pricing approach, process and common questions, see rooftop unit replacement in Denver.

Start a rooftop unit replacement project in Greenwood Village

Send drawings, a scope or a site address in Greenwood Village. We reply with next steps, the information we need and a time for a plan review or site walk, and the scope is in writing before anything is scheduled.

Greenwood Village rooftop unit replacement questions

Do you replace RTUs around the Denver Tech Center?

Yes. We replace rooftop units across Greenwood Village, including the Denver Tech Center, Greenwood Plaza, the Orchard Road and Belleview Avenue office corridors and the Landmark mixed-use district.

Can Greenwood Village changeouts happen after hours?

Yes. Most Greenwood Village changeouts are scheduled early mornings, weekends or after hours.

What is a curb adapter?

A transition that lets a new unit with a different footprint sit on the existing roof curb, which avoids cutting and re-flashing the roof.

How many units in one day?

Often several, depending on unit size, access and crane reach. Grouping units into one crane day lowers the lift cost per unit.

Do you maintain RTUs afterward?

Yes. Planned maintenance agreements cover filters, belts, coils, economizers and safeties, with a written report after each visit.